Number |
Model |
RCDS-100V100A |
1 |
Number of Main Channels |
4CH / Rack |
2 |
output power |
Maximum power 10kW for channel operation; no time limit
|
3 |
output power stability
|
±(0.1%FS+0.1%RD) |
4 |
Input side power quality
|
power factor |
>99%loaded to capacity |
Total harmonic distortion rate |
≤5%loaded to capacity |
6 |
Energy consumption parameters |
Standard sine wave feedback energy, high efficiency (optimum efficiency 90%)
|
7 |
Main Channel Working Mode
|
Charging: constant current charging CC, constant voltage charging CV, constant current constant voltage charging CCCV, constant current constant voltage charging process conversion needs to achieve no impulse voltage current;
Discharge: constant current discharge CD, constant power amplifier CP, constant resistance discharge CR, constant voltage constant current discharge
pause n.
Keywords Working condition test; Pulse test;
|
8 |
Main channel voltage |
Single Channel Measurement Range |
0.2V-100V, with continuously adjustable intermediate values (wide test range, suitable for various battery module test requirements)
|
Minimum discharge voltage |
7V |
precision |
±(0.05%FS+0.05%RD) |
Resolution |
1mV |
Main channel current |
Single Channel Measurement Range |
-200A~+200A |
Minimum output current |
150mA |
precision |
±(0.05%FS+0.05%RD) |
resolution ratio |
1mA |
response time |
<10ms |
apolegamy assist
voltage
|
Number of channels
|
32 |
Measurement range
|
DC:0-5V |
Measurement precision
|
±(0.05%FS+0.05%RD) |
resolution ratio
|
1mV |
apolegamy assist
temperature
|
number of tracks |
8 |
Measuring Range |
﹣50℃~300℃ |
Accuracy in measurement |
±1℃ |
Resolution ratio |
0.1℃ |
time |
Data acquisition resolution |
10ms |
9 |
Equipment communication mode
|
Support LAN communications |
Battery BMS communications
|
Support CAN 2.0A, CAN 2.0B; RS485 communications
Supports DBC import, enables data reading with BMS CAN and participates in process control
|
10 |
Control control program
|
Support power down data protection, support for power failure, manual stop, data file succession testing, online modification of step parameters
|
Safety protection conditions can be set. Parameters include: voltage lower limit, voltage upper limit, current lower limit, current upper limit temperature upper limit
|
Auxiliary channel / BMS protection conditions can be set. The parameters can include: voltage upper limit, voltage lower limit, temperature upper limit, temperature lower limit, single cell pressure difference
|
cycle index |
MAX10000 |
Programmable steps |
MAX10000 |
Loop nesting |
Maximum 10 floors |
Step Time Range
|
Unlimited support for h, min, s format
|
Minimum interval for data recording |
Time ≥10ms, voltage ≥0.1% FS, current ≥0.1% FS, and supporting step-by-step setting of recording conditions |
Programming Features
|
Each work step may have one or more exits
|
11 |
work pattern |
Constant-current charging |
Battery pack voltage, time, capacity, electricity, monomer temperature, monomer voltage, cell voltage difference, RSOC,- V up to |
Constant-voltage charging |
Current, time, capacity, electricity, monomer temperature, monomer voltage, cell voltage difference, RSOC,- V up to |
Constant current and constant voltage charging |
Current, time, capacity, electricity, monomer temperature, monomer voltage, cell voltage difference, RSOC,- V up to |
Shelve |
End of time |
Constant-current discharge |
Battery pack voltage, time, capacity, electricity, cell temperature, cell voltage, cell voltage difference up to |
Constant power discharge |
Battery pack voltage, current, time, capacity, electricity, cell temperature, cell voltage, cell voltage difference up to |
Constant resistance discharge |
Battery pack voltage, current, time, capacity, electricity, cell temperature, cell voltage, cell voltage difference up to |
12 |
Data presentation
|
Circular list |
Have cycle serial number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, charge/discharge level average voltage, etc. |
List of processes
|
There are process serial number, operation mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc. |
Detailed list
|
There are record number, system time, accumulative time, voltage, current, energy, monomer temperature1--monomer temperature n, monomer voltage 1-- monomer voltage n, monomer voltage extreme difference, etc. |
13 |
Data export |
Data can be led into excel, TXT, chart file, can provide charge-discharge curve, capacity decay rate, cycle life curve, charge-discharge voltage, current, capacity-time and other ways of data analysis curve and data list |
14 |
Data save mode |
The user can customize the name and the data save path, and the data can be saved by file |
15 |
Type of curve |
X coordinates: total time, charge/discharge time/capacity, number of cycles |
Y coordinates: total voltage, current, capacity, energy, monomer voltage 1-monomer voltage n, monomer temperature 1-monomer temperature n |
16 |
Input protection |
Over-voltage, over-current, lack of phase, over-temperature, protection alarm; |
Output protection |
Over-voltage, over-current, short-circuit, capacity, temperature, monomer overvoltage, monomer under-voltage protection; without detecting the battery voltage, no output; |
Power-off protection |
After the external power is cut off, the battery and the equipment are automatically disconnected to avoid the accident caused by re-powering. |
Hardware protection |
Power off protection, open circuit protection, short circuit protection; battery connection back, fault protection, over-current protection, overvoltage protection, over-temperature protection, hardware overvoltage over-current protection |
Short-circuit protection
|
External short circuit; |
Software protection |
Power down data protection, call continuation, overvoltage over-discharge protection, over-current protection, capacity protection, over-temperature protection, voltage trend abnormal protection, current trend abnormal protection, current fluctuation abnormal protection, voltage fluctuation abnormal protection, charge voltage rise speed abnormal protection, discharge current drop speed abnormal protection, equipment communication abnormal protection, auxiliary module communication abnormal protection |
Alarm function |
The hardware has the functions of emergency cutting off switch, automatic shutdown after power off, automatic load connection and disconnection. |
17 |
Cooling-down method
|
Forced air cooling |